Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor

Product Details
Customization: Available
Display: LED
Appliance: Water Treatment, Sewage Treatment, Fish Farming...

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Experienced Team
The supplier has 11 foreign trading staff(s) and 9 staff(s) with over 6 years of overseas trading experience
Multi-language Pioneer
3 languages freely used by foreign trade staff. include: English, Korean, Russian
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (28)
  • Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor
  • Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor
  • Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor
  • Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor
  • Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor
  • Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor
Find Similar Products

Basic Info.

Model NO.
PCEC01
Portable
Non Portable
Certification
RoHS
Type
Dissolved Oxygen Meter
Measuring Range
0 - 20mg/L,0 - 200%,0 - 400hpa
Resolution
0.01mg/L,0.1%,1hpa
Accuracy
±1.5%Fs
Repetition
±0.5%Fs
Temperature Measurement Type
Ntc 10K/PT1000
Output Type
4 - 20mA, RS485
Max.Loop Resistance
750Ω
Communication Protocol
Standard Modbus-RTU (Customizable)
Power Supply
AC220V, 50Hz/60Hz (Optional 24V)
Alarm Relay
AC250V, 3A
Transport Package
Standard Export Packing
Origin
China
Production Capacity
5000 Pieces/Month

Product Description

PCEC01  Online Conductivity/Resistivity Controller
 

Product overview  
PCEC01 EC online analyzer is an intelligent online chemical analyzer. The cap of the sensor is coated with a luminescent material. Blue light from an LED illuminates the luminescent chemical. The luminescent chemical instantly becomes excited and releases red light. The time and intensity of red light are inversely proportional to the concentration of oxygen molecules, So the concentration of oxygen molecules is calculated.

Features

Support dissolved oxygen(DO), saturation(SAT), oxygen partial pressure(OPP) and temperature measure.
Support upper/lower limit control, transmitting output, RS485 communication.
Configurable manual and auto temperature offset function.
Configurable upper/lower limit alarm and delay.
Configurable hummer and LCD backlight switch.
Optional language, Chinese and English.
Zero oxygen and full-scale calibration.

Applications
Sewage treatment plants:
Oxygen measurement and regulation in the activated sludge basin for a highly efficient biological cleaning process
Environmental protection water monitoring:
Oxygen measurement in rivers, lakes or seas as an indicator of the water quality
Water treatment:
Oxygen measurement for status monitoring of drinking water for example (oxygen enrichment, corrosion protection etc.)
Fish farming:
Oxygen measurement and regulation for optimum living and growth conditions
 
Measuring principle

• Sensor design:
- Oxygen-sensitive molecules (markers) are integrated in an optically active layer (fluorescence layer).
- The surface of the fluorescence layer is in contact with the medium.
- The sensor optics are directed at the underside of the fluorescence layer.
• There is an equilibrium between the oxygen partial pressure in the medium and that in the fluorescence layer:
- If the sensor is immersed in the medium, the equilibrium is established very quickly.
• Measuring process:
- The sensor optics send green light pulses to the fluorescence layer.
- The Oxygen-sensitive molecules instantly becomes excited and releases red light.
- The duration and intensity of the response signals is directly dependent on the oxygen contents and the partial pressure.
- If the medium is free from oxygen, the response signals are long and very intense.
- Oxygen molecules quench the Oxygen-sensitive molecules. As a result, the response signals are shorter and less intense.
• Measurement result:
- The sensor returns a signal that is in proportion to the oxygen concentration in the medium.
- The medium temperature and air pressure are already taken into account calculated in the sensor.
- In addition to the standard values of concentration, saturation index and partial pressure,
the sensor also returns a raw measured value in μs. The value corresponds to the decay time of the fluorescence and is approx. 20 μs in air and approx. 60 μs in media free from oxygen.
 
Technical specifications
Measurement variables Dissolved oxygen, saturation, oxygen partial pressure
Measuring range 0 - 20mg/L,0 - 200%,0 - 400hPa
Resolution 0.01mg/L,0.1%,1hPa
Accuracy ±1.5%FS
Repetition ±0.5%FS
Temperature
measurement type
NTC 10K/PT1000
Auto A/manual H
Measuring range
-10 - 60ºC Resolution: 0.1ºC Correction
accuracy: ±0.5ºC
Output type 1 4 - 20mA current transmission output
Max.loop resistance 750Ω
Current Output Accuracy 0.1%FS
Output type 2 RS485 digital signal output
Communication protocol Standard MODBUS-RTU (customizable)
Power supply AC220V±10%, 50Hz/60Hz (optional 24V±10%)
Alarm relay AC250V, 3A
 
Installation method



            Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor

2 Dissolved oxygen sensor
       
Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor
 
Identification of terminal

Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor

                           Wiring diagram


+12VDC: Power supply of dissolved oxygen electrode
AGND: Power negative of dissolved oxygen electrode
RS485-A: Dissolved oxygen electrode communication-A
RS485-B: Dissolved oxygen electrode communication-B
NC: Null
RS485(A+): RS485 communication interface A+
Optical Dissolved Oxygen Online Analyzer - Operation Manual
RS485(B-): RS485 communication interface B-
I(+):4-20mA output port +
I(-): 4-20mA output port -

HO: High alarm of normal open relay
HC: High alarm of normal close relay
COM: Common port
LO: Low alarm of normal open relay
LC: Low alarm of normal close relay
COM: Common port
220V L: AC220V fire wire
NC: Null
220V N: AC220V zero wire

About Us:
Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor


Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor


Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor
Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor
Certifications:
Electrical Conductivity Meter Waste Water Online Conductivity Analyzer Sensor


FAQ:
1.    Q: Are you manufacturer or trading company?
        A: We are manufacturer which focuses on pressure sensor for 33 years.
2.    Q: What international certificates do you have?
        A: ISO9001, CE, RoHS Certificated.
3.    Q: What is your production capacity?
        A: We produced 1500000 pieces pressure sensor in year 2017.
4.    Q: What is the lead time of your product?
        A: Stocks are available for some products. The typical lead time is 8~14 working days for product without customization. 
       Note: lead time may vary base on different products. Please contact us for detailed lead time. 
5.    Q: What is the warranty of your products?
       A: Our warranty time is 18 months after shipment.
6.    Q: Do you provide customized products?
       A: Yes, we can laser mark your logo, model and product information according to your requirement. We provide OEM and ODM service.

 