The Urea Dosing Pump Pressure Transmitter is a type of 16mm medium isolated silicon piezoresistance pressure sensor designed for the automobile, and realizes the transmission to the sensing element through SS316L diaphragm; the Urea Dosing Pump Pressure Transmitter is designed specially for high performance and low pressure application. The custom-made ASIC is used for temperature compensation, offset correction, and provides the amplified output of 0.5 to 4.5V. This model may also come with a cable if desired.
Performance specifications |
PARAMETERS |
MIN |
TYP |
MAX |
UNITS |
NOTES |
Supply voltage |
4.75 |
5.0 |
5.25 |
V |
|
Supply current |
|
|
12.5 |
mA DC |
|
Ratiometric output |
0.5 |
|
4.5 |
V |
1 and 5 |
Accuracy |
-0.5 |
|
0.5 |
%FS |
2 |
Total error band |
-2.0 |
|
2.0 |
%FS |
3 |
Compensated temp. |
-7 |
|
105 |
ºC |
|
Performance specifications (cont.) |
Operating temp. |
-40 |
|
105 |
ºC |
|
Storage temp. |
-40 |
|
125 |
ºC |
|
Insulation resistance (500V) |
10 |
|
|
MΩ |
4 |
Reverse voltage |
|
|
18 |
V |
|
Overvoltage protection |
|
|
18 |
V |
|
Short circuit protection |
Continuous |
|
Output noise@1Khz |
|
13 |
- |
mV |
|
Response time (10% to 90%) |
|
1.0 |
- |
mS |
|
Long-term stability |
-0.15 |
|
0.15 |
%FS/year |
|
Output load |
|
47 |
- |
KΩ |
|
Unless otherwise specified: Supply voltage: 5V; ambient temperature: 25ºC after preheating for 10 seconds.
Notes:
- Ratiometric to supply voltage, pressure transfer function at 5V voltage supply; see Chart 1;
- The accuracy includes non-linearity, hysteresis and repeatability;
- TEB includes all accuracy errors, thermal errors, span and zero tolerance over the compensated range;
- Between the sensor body and any pins of the connector;
- This product can be configured according to the customer's OEM requirements; see Chart 2.
Environmental specifications |
PARAMETERS |
MIN |
TYP |
MAX |
UNITS |
NOTES |
Pressure overload |
|
|
2X |
|
6 |
Pressure burst |
|
|
3X |
|
7 |
Pressure cycles |
1M |
|
- |
|
|
Material |
Port: 316 /316L ST STL |
|
Sealing: FKM Fluoroelastomer 70 (O-ring) |
|
Housing: PA66+30%GF |
|
Freeze protection |
Available |
8 |
Notes:
- The maximum pressure that can be applied without changing the sensor performance or accuracy;
- The maximum pressure that can be applied to the transducer without rupture of either the sensing element or the transducer;
- The measured medium dead volume that exceeds 350mm3 may damage the sensor in the frozen state.
EMC performance standard: Output change < ±1.5% FS@RT |
|
ESD ISO 10605 |
8kV Contact/15kV Air |
|
|
EMS ISO 11452-2 |
Level V, 140V/m, 200MHz-3.2GHz |
|
|
BCI ISO 11452-4 |
d=150mm, d=450mm, d=750mm Frequency range: 1MHz-400MHz Modulation CW, AM Severity level V (200mA) |
|
|
|
|
|
About Us:
Certifications:
FAQ:
1. Q: Are you manufacturer or trading company?
A: We are manufacturer which focuses on pressure sensor for 33 years.
2. Q: What international certificates do you have?
A: ISO9001, CE, RoHS Certificated.
3. Q: What is your production capacity?
A: We produced 1500000 pieces pressure sensor in year 2017.
4. Q: What is the lead time of your product?
A: Stocks are available for some products. The typical lead time is 8~14 working days for product without customization.
Note: lead time may vary base on different products. Please contact us for detailed lead time.
5. Q: What is the warranty of your products?
A: Our warranty time is 18 months after shipment.
6. Q: Do you provide customized products?
A: Yes, we can laser mark your logo, model and product information according to your requirement. We provide OEM and ODM service.